304/316Stainless Steel Threaded Malleable Sleeve Connector Straight Joint Quick Fitting
10g/h household shopping mall ozone generator air purification formaldehyde odor removal O3 disinfection sterilizer
Water filter accessories ro water purification system quick fitting pressure tank ball valve
4 stage reverse osmosis hot and cool water dispenser RO water cooler with ultraviolet
2 stage 10 inch jumbo whole house pre-filtration
Model:AD-BW-8040
Maximum Working Pressure:600 psi (4.14 MPa)
FR series, the surface of this membrane was treated by special technology, which changed the electric charge and smoothness of the membrane surface, increased the hydrophilicity of the membrane surface, thus reducing the contamination of pollutants and microorganisms on the membrane surface, and achieving the purpose of reducing the contamination of membrane components and prolonging the service life.
BW series of membrane elements Operation Limits & Conditions
Model
Membrane ft²(m²)
Average Permeate GPD (m3/d)
Stable Rejection %
Min. Rejection %
AD-BW-4021
36 (3.3)
950 (3.6)
99.5
99
AD-BW-4040
85 (7.9)
2000 (7.6)
99.5
99
AD-BW-8040
400 (37)
10500 (39.5)
99.5
99
AD-BW-4040FR
85 (7.9)
1900 (7.2)
99.6
99
AD-BW-8040FR
400 (37)
9500 (36)
99.6
99
BW series of membrane elements Testing Conditions:
Max. Working Pressure
600psi(4.14MPa)
Max. Feed Water COD
10ppm
Max. Feed Water Flow
Max. Feed Water BOD
5ppm
Max. Feed Water TOC
10ppm
Max. Feed Water Temperature
45℃
Residual Chlorine Concentration of Feed Water
< 0.1ppm
Max. Feed Water TDS
5000ppm
PH Range of Feed Water During Continuous Operation
2 ~ 12
Max. Feed Water Hardness
60ppm
15psi(0.1MPa)For8040、4040
Max. Feed Water SDI 15
5
10psi(0.07MPa)For 4021
Max.Turbidity NTU
1
Testing Pressure
225 psi (1.5MPa)
Temperature of Testing Solution
25 ℃
Concentration of Testing Solution (NaCl)
2000ppm
pH Value of Testing Solution
7.5
Recovery Rate of Single Element
15%(8040、4040、2540);8% (4021、2521)